Titrator KEM MKH-710M

Type Hybrid Karl Fischer Moisture Titrator
Model MKH-710M
Coulometric titration Measuring method :
Karl Fischer Coulometric titration 

Measuring range :
Water content : 1μg to 300mg
Bromine : 8μg to 300mg *1

Precision :
RSD : less than 0.3% (n=10)(for measurements of 1mgH2O)
Display resolution : 0.1μg

Volumetric titration Measuring method :
Karl Fischer Volumetric titration 

Measuring range :
Water content : 0.1 to 500mg H2O(depends on KF reagent factor)
Concentration : 1ppm to 100% H2O

Burette precision :
Volume : 10mL
Discharge precision : ±0.015mL
Repeatability : ±0.005mL

Hybrid titration Measuring method :
Karl Fischer Coulometric titration
Karl Fischer Volumetric titration 

Measuring range :
Water content : 1μg to 500mg H2O

Precision :
RSD : less than 0.3% (n=10)
(for measurements of 10mgH2O)
(Karl Fischer reagent factor 3mg/mL)
Display resolution : 0.1μg

Factor measurement of reagent by electrolysis Measuring method :
Factor measurement of reagent by electrolysis 

Measuring range :
KF reagent : Reagent factor from 1 to 5
(With the provisions of dose volume)

Precision :
RSD : less than 1.0% (n=3)
(Dose volume 0.5mL, Reagent factor 3mg/mL)

Method 120
Key operation Touch panel
Displays 8.4-inch color LCD 800 x 600 dots
English / Japanese / Mandarin Chinese / Korean
Simultaneous 4-channel display (Can also display Automatic Potentiometric Titrator simultaneously)
Extensibility Measuring instrument :
Automatic Potentiometric Titrator (AT-710) , Karl Fischer Moisture Titrator (MKV-710/MKC-710/MKH-710)
Three of these instruments can be added.
Data storage 500 samples
GLP conformance Registration of operator / User group administration
Titrant : Reminder of factor measurement date / Alarm to indicate remaining reagent / Reminder of piston replacement date / Reminder of reagent replacement date / History of factor measurement / Reminder of expiration
Check performance : Reminder of scheduled check date / Record of check results
Management of conduction time : Display of operating time
External I/O RS-232C port x4 :
for Dot matrix printer , Electronic balance , Data Capture Software (SOFT-CAP) , Multiple sample chager , Evaporator 

USB ×1 :
for USB flash drive , A4 printer , Thermal printer , Keyboard , Barcode reader , Foot switch , USB HUB

SS-BUS :
Automatic piston burette : Can control max 2 burette drives (Including two built-in burette drives)

LAN ×1 :
for Personal computer (PC)

Power Supply Main unit: DC24V(Main unit), AC100-240V±10%, 50/60Hz(AC adapter)
Printer: DC7V(Main unit), AC100V±10%, 50/60Hz(AC adapter)
Power Consumption Main unit: Approx. 30W, Printer: Approx. 7W
Dimensions
(Excluding tube)
Touch panel controller: 225(W)×190(D)×42(H)mm
Titration unit: 141(W)×292(D)×377(H)mm
Stirrer/ Cell: 107(W)×206(D)×364(H)mm
Solvent change unit: 240(W)×140(D)×400(H)mm
Printer: 106(W)×180(D)×88(H)mm
Weight Touch panel controller: Approx. 1.5kg
Titration unit: Approx. 4kg
Stirrer/ Cell: Approx. 2kg
Solvent change unit: Approx. 0.6kg
Printer: Approx. 0.4kg

Guaranteed Safe Checkout

Submit Your Inquiry

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Features & Compatibility

    Titrator: Precision, Automation, and Reliability in Modern Chemical Analysis

    Titrator KEM MKH-710M is a highly specialized laboratory instrument used to perform titration—one of the most essential analytical methods for determining the concentration of an analyte in a sample. Whether in pharmaceuticals, chemical manufacturing, food and beverage quality control, or environmental testing, a titrator provides accurate, repeatable, and efficient measurements while minimizing manual effort and operator error.

    In this comprehensive guide, we explore what a titrator is, its core features, applications, and the benefits it brings to laboratory environments.


    What is a Titrator?

    A titrator is a laboratory instrument that automates or semi-automates the process of titration by dispensing a titrant (a solution of known concentration) into a sample until the reaction reaches a defined endpoint. Using sensors such as pH, conductivity, or redox electrodes, the titrator continuously monitors changes in the solution to detect the endpoint with high accuracy.

    Unlike manual titration—which relies on visual cues and operator judgment—a modern titrator uses advanced sensors and computational analysis to ensure precise, repeatable results while reducing human variability.


    Key Features of a Modern Titrator

    1. Automated or Semi-Automated Titrant Delivery

    Titrators deliver titrant with high precision, often controlled by micro-dosing systems that respond to real-time sensor feedback. This ensures consistent endpoint detection across all sample types.

    2. Support for Multiple Titration Techniques

    Modern titrators can perform a wide range of titration methods, including:

    • Acid–Base Titration: Measures pH changes for acid or base concentration determination.

    • Redox Titration: Used in oxidation–reduction analyses.

    • Complexometric Titration: Ideal for determining metal ions in water, food, or industrial solutions.

    • Precipitation Titration: Suitable for halide determination and reactions forming solid precipitates.

    • Karl Fischer Titration (Coulometric or Volumetric): Used to measure moisture content with extreme accuracy.

    3. Advanced Endpoint Detection

    With high-precision electrodes and optical sensors, titrators ensure accurate endpoint identification even in complex or multi-step reactions.

    4. Programmable Methods & Custom Protocols

    Users can store predefined titration methods or create customized protocols, allowing quick setup and consistent performance across repetitive tests.

    5. Data Logging, Reporting & Digital Integration

    Modern titrators store key parameters such as titrant volume, sample ID, and endpoint value. Many models integrate with:

    • LIMS systems

    • USB/PC software

    • Cloud-based data platforms

    This supports compliance with industry standards and simplifies audit trails.

    6. Sample Automation Compatibility

    Titrators can be paired with autosamplers or sample changers, enabling fully automated batch processing—ideal for busy laboratories with high throughput demands.

    7. Intuitive Interface

    Touchscreen displays, guided workflows, and preprogrammed methods make titrators user-friendly, even for technicians with limited experience.


    Applications of Titrators

    1. Pharmaceutical Industry

    Used for analyzing APIs, excipients, drug formulations, and moisture content (Karl Fischer). Ensures final products meet regulatory standards for potency, purity, and stability.

    2. Food & Beverage Industry

    Titrators monitor parameters such as acidity, salt content, preservatives, sugar levels, and moisture—critical for taste, shelf life, and safety.

    3. Chemical & Petrochemical Industry

    Ideal for analyzing fuels, oils, lubricants, surfactants, and industrial chemicals. Helps maintain product specifications and quality control.

    4. Environmental Monitoring

    Used for testing water quality, soil chemistry, and pollution indicators including alkalinity, chloride levels, dissolved oxygen, and more.

    5. Academic & Research Institutions

    Supports teaching, experimental research, and advanced chemical studies requiring consistent quantitative analysis.


    Benefits of Using a Titrator

    1. Superior Accuracy & Reproducibility

    Automated sensing and dosing systems minimize human error, ensuring consistent results across repeats.

    2. Higher Laboratory Efficiency

    Automation accelerates titration processes and frees personnel to focus on other analytical tasks.

    3. Better Data Management

    Digital documentation enhances traceability and supports regulatory compliance.

    4. Reduced Operator Fatigue

    Eliminates the need for constant manual monitoring, especially in labs handling large numbers of samples.

    5. Versatile Across Industries

    Handles an extensive range of sample types and titration methods, making it suitable for almost any laboratory setting.


    How to Choose the Right Titrator

    1. Titration Method Requirements

    Select a titrator capable of performing your most common titration types—especially if you require Karl Fischer or complexometric titrations.

    2. Sample Volume & Throughput

    High-throughput labs benefit from autosamplers or multi-channel titrators.

    3. Accuracy & Sensitivity

    Choose models with high-precision electrodes and fine-resolution dosing systems for sensitive analyses.

    4. Software Integration

    Ensure compatibility with your LIMS or digital environment for seamless data transfer.

    5. Ease of Use

    User-friendly interfaces, preprogrammed methods, and clear workflows reduce training time and setup errors.


    Conclusion

    A titrator is an indispensable tool for modern laboratories requiring accurate and reliable chemical analysis. With automated endpoint detection, advanced data management, multiple titration methods, and high productivity, titrators enhance precision, reduce operator workload, and improve overall laboratory efficiency. Whether used in pharmaceuticals, food production, environmental monitoring, or academic research, a titrator ensures consistent, high-quality analytical results across diverse applications.

    Additional information

    Brand

    KEM

    Customer Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “Titrator KEM MKH-710M”