Oil Karl Fischer Trace Moisture Analyzer KMA/K/10

Features:

  • The trace moisture analyzer of our company meets the requirements of GB/T 7600, SH/T 0255, GB/T6283, SH/T 0246 and other method standards. The Karl Fischer (Coulomb) method was adopted to determine the content of trace amounts of moisture in liquids of different properties. The trace moisture analyzer has the advantages of high measurement accuracy, fast speed, stable and reliable measurement data, and is widely used in petroleum, chemical, electric power, environmental protection, medicine and other departments. It can quickly determine the moisture content of alcohols, oils, lipids, ethers, esters, acids, alkanes, benzenes, amines, organic solvents, pesticides, phenols, pharmaceutical raw materials and other chemical, petroleum, pharmaceutical, pesticide and other products.
Specification
Kiparma Model KMA/K/10
Accuracy (%): 0.3
Measuring Range : 3.0 µg to 100mg
Resolution (µg) : 0.1
Electrolytic Current (mA) : 0 to 400
Maximum electrolytic speed (µg) : 40
Power Supply: AC220V ± 20%
External Size (W×D×H) (mm) : 320×240×200

Guaranteed Safe Checkout

Submit Your Inquiry

    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Features & Compatibility

    Precision Moisture Analysis with Oil Karl Fischer Trace Moisture Analyzer KMA/K/10

    Accurate moisture content analysis is vital across industries such as pharmaceuticals, food, chemicals, and petrochemicals. Whether you’re ensuring product quality, meeting regulatory requirements, or conducting research, the Oil Karl Fischer Trace Moisture Analyzer KMA/K/10 method offers a precise and reliable solution for determining water content. Known as the gold standard in moisture analysis, Karl Fischer titration can detect even trace amounts of water in solids, liquids, and gases. This guide will delve into the key features, benefits, and applications of Karl Fischer titration, helping you understand its critical role in modern laboratories.

    What is Karl Fischer Titration?

    Karl Fischer titration is a well-established analytical technique used to measure the water content in various substances. Developed by the German chemist Karl Fischer in 1935, this method is based on the quantitative reaction of water with iodine and sulfur dioxide in the presence of a base, typically in methanol. The process can be performed using either volumetric or coulometric titration, depending on the concentration of water in the sample. Karl Fischer titration is highly regarded for its accuracy, specificity, and ability to measure very low levels of moisture.

    Types of Karl Fischer Titration

    1. Volumetric Karl Fischer Titration: Ideal for samples with higher water content (usually above 1%). The titration involves adding a reagent until the reaction with the water is complete, and the amount of reagent used is proportional to the water content.
    2. Coulometric Karl Fischer Titration: Best suited for samples with very low water content (as low as 0.001%). It measures water by generating iodine electrochemically in situ, with the amount of iodine produced directly correlating to the amount of water present.

    Key Features of Oil Karl Fischer Trace Moisture Analyzer KMA/K/10

    1. High Sensitivity and Accuracy: Capable of detecting water levels from a few parts per million (ppm) to several percent, providing precise moisture analysis for a wide range of samples.
    2. Versatility: Suitable for analyzing various sample types, including solids, liquids, and gases, making it a versatile tool in different industries.
    3. Rapid Analysis: Offers quick results, often within minutes, allowing for efficient testing and faster decision-making in production and quality control processes.
    4. Automation Capabilities: Many modern Karl Fischer titrators are equipped with automated features, including sample handling and data logging, improving efficiency and reducing the potential for human error.
    5. Compliance with Standards: Meets international standards such as ASTM, ISO, and USP, ensuring that the moisture analysis is accurate, reliable, and compliant with industry regulations.

    Benefits of Using Oil Karl Fischer Trace Moisture Analyzer KMA/K/10

    1. Exceptional Accuracy: Provides precise moisture content measurement, which is critical for ensuring product quality and consistency.
    2. Wide Range of Applications: Suitable for various industries, including pharmaceuticals, food, chemicals, and more, making it a go-to method for moisture analysis.
    3. Minimal Sample Preparation: Requires only minimal sample preparation, streamlining the testing process and saving time.
    4. Reduces Waste: Efficient use of reagents and the ability to analyze small sample sizes reduce waste, making the process more cost-effective.
    5. Compliance and Quality Assurance: Helps manufacturers meet stringent regulatory requirements and maintain high standards of quality control.

    Applications of Karl Fischer Titration

    1. Pharmaceuticals: Ensures the correct moisture content in drugs and active pharmaceutical ingredients (APIs), which is crucial for stability and efficacy.
    2. Food and Beverage: Determines the water content in food products to ensure quality, shelf life, and compliance with labeling regulations.
    3. Chemicals: Measures moisture in solvents, oils, and other chemicals, where water content can significantly affect product performance.
    4. Petrochemicals: Analyzes the water content in petroleum products and fuels, where moisture can lead to corrosion and other issues.
    5. Cosmetics: Ensures the stability and effectiveness of cosmetic products by accurately measuring moisture levels.
    6. Environmental Testing: Used in the analysis of water content in environmental samples, including soil and air.

    Choosing the Right Karl Fischer Titrator

    When selecting a Karl Fischer titrator, consider factors such as the expected range of water content in your samples, the type of samples you will be analyzing, and the desired level of automation. Consulting with manufacturers or technical experts can help you choose the best system to meet your laboratory’s specific needs.

    Conclusion

    Karl Fischer titration remains an indispensable tool for precise moisture analysis across various industries. Its high accuracy, versatility, and compliance with international standards make it the preferred method for detecting water content in a wide range of substances. By investing in a Karl Fischer titrator, you ensure reliable, efficient, and accurate moisture measurements, supporting quality control, regulatory compliance, and product development.

    For expert advice on selecting the best Karl Fischer titrator for your needs, contact our specialists today.

    Additional information

    Brand

    Kiparma

    Customer Reviews

    Reviews

    There are no reviews yet.

    Be the first to review “Oil Karl Fischer Trace Moisture Analyzer KMA/K/10”